Skip to main content
Article

FABRICATION OF HOLLOW GLASS MICROSPHERES WITH HIGH ASPECT RATIO BY LIQUID DROPLET METHOD

Qiu Longhui, FU Yi bei, WANG Xiao lin, WEI Sheng, SHI Tao Institute of Nuclear Physics and Chemistry,CAEP,P
1999en
ABI

Abstract

The quantitative relationship between out diameter(O.D.) and thickness of hollow glass microspheres(HGM) made by liquid droplet method is given. The operation conditions,such as distributions of temperature and purge gas velocity in the furnace, concentrations of solution, and the operation conditions of the droplet generator, are experimentally optimized, under which HGM is produced with O.D. of 300~450μm, wall thickness of 0.7~1.2μm, aspect ratio of 300~700, surface roughness better than 10nm, concentricity better than 97%,sphericity higher than 99%, and out and inner failure pressures more than 0.91MPa and 0.43 MPa respectively.

Topics