Skip to main content
Article

Investigation of the error measurement of ultrasonic sensors for measuring water flow in open canals of irrigation systems

Anvar DjalilovTashkent Institute of Irrigation and Agricultural Mechanization Engineers, 39, K.Niyaziy str. Tashkent, 100000, UzbekistanE SobirovTashkent Institute of Irrigation and Agricultural Mechanization Engineers, 39, K.Niyaziy str. Tashkent, 100000, UzbekistanO NazarovTashkent Institute of Irrigation and Agricultural Mechanization Engineers, 39, K.Niyaziy str. Tashkent, 100000, UzbekistanMurodjon BegmatovTashkent Institute of Irrigation and Agricultural Mechanization Engineers, 39, K.Niyaziy str. Tashkent, 100000, UzbekistanM AbdullaevTashkent Institute of Irrigation and Agricultural Mechanization Engineers, 39, K.Niyaziy str. Tashkent, 100000, UzbekistanS UrolovTashkent State Technical University, University str. 2, Tashkent, 100000, Uzbekistan
ABI

Abstract

This paper analyzes ultrasonic flow meters that provide stability of metrological characteristics during operation, low cost of meter maintenance, high reliability and sensitivity, and high performance in large diameter pipes and open chanels. Based on the analysis, the requirements of the reclamation systems to the sensors, the causes of the error are formed. The difference between the speed of sound in the opposite direction of the flow direction or in the direction of flow in the ultrasonic sensors was studied. The measurement errors of ultrasonic sensors currently widely used in open canals are investigated graphically. Based on the analysis results, it is recommended to use an ultrasonic sensor suitable for the extreme conditions of our country.

Topics

Identifiers

Citations and references