Skip to main content
Article

Experimental validation of an innovative approach in biokinetics study for personalised dosimetry of molecular radiation therapy treatments

C. Mancini-TerraccianoNational Institute of Nuclear PhysicsAntonio AmbrosinoNational Institute of Nuclear PhysicsL CampanaNational Institute of Nuclear PhysicsB. CassanoIRCCS Regina Elena National Cancer InstituteF. CollamatiNational Institute of Nuclear PhysicsR. FacciniNational Institute of Nuclear PhysicsG. IaccarinoIRCCS Regina Elena National Cancer InstituteR. MirabelliNational Institute of Nuclear PhysicsS. MorgantiNational Institute of Nuclear PhysicsFrancesca NicolantiNational Institute of Nuclear PhysicsMassimiliano PacilioAzienda Ospedaliera-Universitaria Policlinico Umberto IA. SorianiIRCCS Regina Elena National Cancer InstituteE. Solfaroli CamillocciItalian National Institute of Health
ABI

Abstract

Abstract One of today’s main challenges in molecular radiation therapy is to assess an individual dosimetry that allows treatment to be tailored to the specific patient, in accordance with the current paradigm of ‘personalized medicine’. The evaluation of the absorbed doses for tumor and organs at risk in molecular radiotherapy is typically based on MIRD schema acquiring few experimental points for the assessement of biokinetic parameters. WIDMApp, the wearable individual dose monitoring apparatus, is an innovative approach for internal dosimetry based on a wearable radiation detecting system for individual biokinetics sampling, a Monte Carlo simulation for particle interaction, and an unfolding algorithm for data analysis and integrated activity determination at organ level. A prototype of a WIDMApp detector element was used to record the photon emissions in a body phantom containing 3 spheres with liquid sources ( 18 F, 64 Cu and 99 m Tc) to simulate organs having different washout. Modelling the phantom geometry on the basis of a CT scan imaging, the Monte Carlo simulation computed the contribution of each emitting sphere to the signal detected in 3 positions on the phantoms surface. Combining the simulated results with the data acquired for 120 h, the unfolding algorithm deconvolved the detected signal and assessed the decay half-life ( T 1/2 ) and initial activity values ( A (0)) that best reproduces the observed exponential decays. A 3%–18% level of agreement is found between the actual A (0) and T 1/2 values and those obtained by means of the minimization procedure based on the Monte Carlo simulation. That resulted in an estimation of the cumulated activity <15%. Moreover, WIDMApp data redundancy has been used to mitigate some experimental occurrences that happened during data taking. A first experimental test of the WIDMApp approach to internal radiation dosimetry is presented. Studies with patients are foreseen to validate the technique in a real environment.

Topics

Identifiers

Citations and references

Cited by 014 references
Metrics — AkademScholar · Coming soon