Improvement of the design of the unit for cleaning the air stream from dust at a cotton ginnery

Orif Zh. MurodovTashkent Institute of Textile and Light Industry, 5, Shokhzhakhon street, Tashkent city, 100000, Republic of UzbekistanAziza Sh. AdilovaTashkent Institute of Textile and Light Industry, 5, Shokhzhakhon street, Tashkent city, 100000, Republic of UzbekistanNozima A. SaidovaBukhara Engineering-Technological Institute, 15, K. Murtazaev street, Bukhara, 200017, Republic of UzbekistanMirhosil M. AgzamovTashkent Institute of Textile and Light Industry, 5, Shokhzhakhon street, Tashkent city, 100000, Republic of Uzbekistan
E3S Web of Conferencesjournal2023en
ABI

Abstract

The article covers research on the design of a dust-cleaning unit using a cyclone and additional water that cleans the air from cotton factories with high efficiency. The history of cyclones for dust air cleaning from cotton ginneries has been studied and deeply analyzed. The composition of the dusty air stream coming out of the cotton ginneries has been studied, and a new improved unit to the cyclone separator according to the dusty air composition has been designed. A new unit design has been developed and positive results has been obtained by simulation using the most modern programs.

Topics

Identifiers

Citations and references

Cited by 013 references
Metrics — AkademScholar · Coming soon