Skip to main content
Article

VARIOUS FACTORS CAN CONTRIBUTE TO INACCURACIES IN ELECTROMAGNETIC CURRENT TRANSDUCERS

Khurshid SattarovResearcher , Tashkent University Of Information Technologies Named After Muhammad Al-Khwarizmi Tashkent , Uzbekistan
ABI

Abstract

In practice often need to decide a solve of problems as to find optimal structural and magnetic parameters of electromagnetic transducers of three-phases current, with characteristics (for example, error) must have a minimum value. In this case, as a rule, in addition alley for input values, sets overall dimensions of electromagnetic transducer of three-phases current. Thus, the task: for given values of the operating range and the overall dimensions of the sensor design dimensions of the individual units on which possible obtain maximum consideration characteristics, such as sensitivity. In this article considered methodology of calculating of optimal parameters of magnetic system of the electromagnetic transducers of three-phases current with foal parallel rods.

Topics

Identifiers

Citations and references

Cited by 01 references