Skip to main content
AkademIndex

Products

For developers

AkademBasesoonOpen API for the ecosystem
Latin
Article

Drainage Characteristics and Heat Transfer Performance of Fin Surfaces in Desert Greenhouse Environments

Mingzhi ZhaoCollege of Energy and Power Engineering, Inner Mongolia University of Technology, Hohhot 010051, ChinaFeng BaiCollege of Energy and Power Engineering, Inner Mongolia University of Technology, Hohhot 010051, ChinaRong YuCollege of Energy and Power Engineering, Inner Mongolia University of Technology, Hohhot 010051, ChinaYu‐Ru LiuCollege of Energy and Power Engineering, Inner Mongolia University of Technology, Hohhot 010051, ChinaYixuan MaDepartment of Power Engineering, North China Electric Power University, Baoding 071003, ChinaYingjie LiuCollege of Energy and Power Engineering, Inner Mongolia University of Technology, Hohhot 010051, ChinaB. S. RasakhodzhaevNational Scientific Research Institute of Renewable Energy Sources, Ministry of Energy of Uzbekistan, Tashkent 100170, Uzbekistan
Energiesjournal2025en
ABI

Abstract

As desertification intensifies, greenhouses in arid regions are increasingly challenged by severe water scarcity and low water utilization efficiency. Traditional greenhouse HVAC systems are often inadequate in efficiently recovering condensate water. This study addressed these challenges by investigating, through wind tunnel experiments, the fin angle and inlet wind speed for optimal condensation and heat transfer performance of a straight-fin heat exchanger in desert greenhouse environments. The experimental findings revealed that under low-temperature conditions, vertical fins facilitated gravity-driven droplet removal, resulting in a maximum condensate amount of 524.2 g within 120 min. Conversely, under high-temperature conditions, a fin angle of 45° optimally balanced turbulent disturbances and liquid film stability, producing a condensate amount of up to 887.1 g in the same timeframe. Additionally, wind speed tests at a 45° fin angle identified a critical wind speed of 1.5 m/s, beyond which the condensate amount significantly decreased. Furthermore, when the fin inclination reached or exceeded 60°, flow separation occurred, reducing the effective heat transfer area and negatively impacting the exchanger efficiency. Overall, the study provides significant insights into water conservation and sustainable environmental utilization by enhancing condensate recovery efficiency.

Topics

Identifiers

Citations and references

Cited by 030 references
Metrics — AkademScholar · Coming soon