Skip to main content
Article

Investigation of factors influencing the operational characteristics of traction transformers

Dilmurod YusupovLLC Scientific and Technical Center of JSC «Uzbekenergo», 100204, Tashkent, UzbekistanOdiljon KutbidinovTashkent State Transport University, Tashkent, UzbekistanShakhboz SamadovTashkent State Transport University, Tashkent, UzbekistanEldor AbdullaevTashkent State Transport University, Tashkent, Uzbekistan
E3S Web of Conferencesjournal2021en
ABI

Abstract

This article presents the results of visual inspections and a brief statistical analysis of the data obtained in order to identify the observed defects in traction transformers of ODTsE 5000 / 25 B and OTsR 5600/25 types in operation in the railway system. The analysis revealed that the main parameters that determine the operational characteristics of traction transformers are windings and insulation. Recommendations for the prevention of faults in traction transformers and increase their service life have been developed.

Topics