Instant synthesis of nitrogen-doped Ti <sub>3</sub> C <sub>2</sub> MXene quantum dots for fluorescence and electrochemical dual-mode detection of norepinephrine with a portable smartphone assay

Murugesan ChandranDepartment of Bionanotechnology, Gachon University, Gyeonggi-do 13120, Republic of KoreaGayathri ChellasamyDepartment of Bionanotechnology, Gachon University, Gyeonggi-do 13120, Republic of KoreaMekala VeerapandianDepartment of Bionanotechnology, Gachon University, Gyeonggi-do 13120, Republic of KoreaBarkavi DhanasekaranDepartment of Bionanotechnology, Gachon University, Gyeonggi-do 13120, Republic of KoreaSaravanan GovindarajuDepartment of Bionanotechnology, Gachon University, Gyeonggi-do 13120, Republic of KoreaKyusik YunDepartment of Bionanotechnology, Gachon University, Gyeonggi-do 13120, Republic of Korea
2024en
ABI

Abstract

Next-generation 2D materials, such as transition metal carbides and nitrides (MXenes), have received increasing attention owing to their physicochemical properties. In this study, we synthesized highly intense fluorescent materials, nitrogen-doped MXene quantum dots (N-MQDs) using an easy and less time-consuming microwave-assisted method. These N-MQDs are spherical, fluorescent, and highly sensitive materials, as confirmed by high-resolution transmission electron microscopy, atomic force microscopy, UV-visible, fluorescence, Fourier transform infrared spectroscopy, X-ray diffraction, Raman spectroscopy, zeta potential, and contact angle measurements. The N-MQDs were used as dual probes for the fluorescence and electrochemical sensing of neurotransmitter norepinephrine (NE-0.1 to 500 μM). The sensing strategy is based on the Förster resonance energy transfer acquired by the N-MQDs, leading to fluorescence quenching at 400 nm. A new emission peak at 500 nm with color changes and NE-to-NE quinone conversion in an electrochemical reaction. Fluorescence and electrochemical analyses were revealed using the human serum sample limit of detection (LOD) values of 40 and 33 nM, respectively. For point-of-care analysis, we developed a smartphone-integrated sensor array to calculate intensity changes, and the relative red/green/blue (RGB) values were measured at different concentrations of NE. The synthesized fluorescent probe is a promising candidate for detecting NE in biofluids. It is highly selective toward NE and is suitable for the early diagnosis of neurological diseases.

Identifiers

Citations and references

Cited by 20 references