Перейти к основному содержанию
AkademIndex

Продукты

Для разработчиков

AkademBaseОткрытый API экосистемы
Статья

Comparison between <sup>99m</sup>Tc-Methoxyisobutyl Isonitrile and <sup>99m</sup>Tc-Methylenediphosphonate Scintimammography for Detection ofBreast Carcino ma

Shao‐Liang ChenDepartment of Nuclear Medicine, Institute of Nuclear Medicine, andWenguan LiuDepartment of Nuclear Medicine, Institute of Nuclear Medicine, andYing MaoDepartment of Nuclear Medicine, Institute of Nuclear Medicine, andWeimin ZhuDepartment of Nuclear Medicine, Institute of Nuclear Medicine, andZhifeng YaoDepartment of Nuclear Medicine, Institute of Nuclear Medicine, andXiaoguang SunDepartment of Nuclear Medicine, Institute of Nuclear Medicine, andYan XiuDepartment of Nuclear Medicine, Institute of Nuclear Medicine, andYiqing YinDepartment of Surgery, Shongshan Hospital, Fudan University, Shanghai, ChinaJunxue ChenDepartment of Surgery, Shongshan Hospital, Fudan University, Shanghai, China
ABI

Аннотация

<i>Objective:</i> The goal of the study was to assess the values of scintimammography with <sup>99m</sup>Tc-methoxyisobutyl isonitrile (<sup>99m</sup>Tc-MIBI) and <sup>99m</sup>Tc-methylenediphosphonate (<sup>99m</sup>Tc-MDP) in detecting breast cancer. <i>Methods:</i> A total of 35 women with clinical findings of suspicious breast lesions were studied with both <sup>99m</sup>Tc-MIBI and <sup>99m</sup>Tc-MDP scintimammography. All patients underwent surgery within 1 week, and the results of the histopathological diagnosis were obtained. <i>Results:</i> Eighteen of 35 abnormalities of the breast were pathologically confirmed as primary breast cancer and 17 as benign lesions. In this group of patients, the sensitivity, specificity and accuracy of <sup>99m</sup>Tc-MIBI scintimammography were 77.8, 88.2 and 82.9%, respectively, while those of <sup>99m</sup>Tc-MDP scintimammography were 72.2, 88.2 and 80.8%, respectively. There was no significant difference between the results of <sup>99m</sup>Tc-MIBI and <sup>99m</sup>Tc-MDP scintimammography. <i>Conclusion:</i> This study demonstrated a high diagnostic accuracy of both <sup>99m</sup>Tc-MIBI and <sup>99m</sup>Tc-MDP scintimammography in detecting breast cancer. Both radiopharmaceuticals can be used as an adjunct method for the noninvasive assessment of breast cancer prior to surgery. However, <sup>99m</sup>Tc-MDP is less expensive and more readily available than <sup>99m</sup>Tc-MIBI.

Перевод пока недоступен

Темы

Идентификаторы

Цитирования и источники