Статья

Synthesis Characterization and Highly Protective Efficiency of Tetraglycidyloxy Pentanal Epoxy Prepolymer as a Potential Corrosion Inhibitor for Mild Steel in 1 M HCl Medium

Rachid HsissouLaboratory of Organic Chemistry, Catalysis and Environment, Department of Chemistry, Faculty of Sciences, Ibn Tofail University, BP 242, Kenitra 14000, MoroccoRedouane LachhabLaboratory of Advanced Materials and Process Engineering, Faculty of Sciences, Ibn Tofail University, BP 242, Kenitra 14000, MoroccoAnouar El MagriEuromed Polytechnic School, Euromed Research Center, Euromed University of Fes, Route de Meknès (Rond point Bensouda), Fès 30000, MoroccoS. EchihiHamid Reza VanaeiArts et Métiers Institute of Technology, CNAM, LIFSE, HESAM University, F-75013 Paris, FranceM. GalaiLaboratory of Advanced Materials and Process Engineering, Faculty of Sciences, Ibn Tofail University, BP 242, Kenitra 14000, MoroccoM. Ebn TouhamıLaboratory of Advanced Materials and Process Engineering, Faculty of Sciences, Ibn Tofail University, BP 242, Kenitra 14000, MoroccoMohamed RafikLaboratory of Organic Chemistry, Catalysis and Environment, Department of Chemistry, Faculty of Sciences, Ibn Tofail University, BP 242, Kenitra 14000, Morocco
2022en
ABI

Аннотация

Anticorrosive protection efficiency of novel tetrafunctional epoxy prepolymer, namely 2,3,4,5-tetraglycidyloxy pentanal (TGP), for mild steel in 1 M HCl medium was assessed through potentiodynamic polarization (PDP), electrochemical impedance spectroscopy (EIS), scanning electron microscope (SEM), energy dispersive X-ray spectroscopy (EDS), contact angle (CA), adsorption isotherm model, temperature effect and thermodynamic parameters. The synthesized TGP was characterized and confirmed by Fourier transform infrared (FTIR) spectroscopy and nuclear magnetic resonance (NMR). The inhibitory efficiencies found at lower concentration of the prepolymer TGP were85% (PDP) and 87.17% (EIS). PDP measurement illustrated that the TGP behaved as a mixed-type inhibitor in the realized solution. SEM and EDS analysis showeda significant decrease in the corrosion of the MS surface in the presence of the inhibitory prepolymer compared with the blank (1 M HCl). Langmuir adsorption isotherm is the most acceptable modelto describe the TGP epoxy prepolymer on the MS area.

Перевод пока недоступен

Идентификаторы

Цитирования и источники

Цитирований: 10Использованных источников: 0