High temperature ultrasonic transducers for imaging and measurements in a liquid Pb/Bi eutectic alloy

R. KažysUltrasound Institute of Kaunas University of Technology, Kaunas, Lithuania. [email protected]A. VoleišisUltrasound Institute, Kaunas University of Technology, Kaunas, LithuaniaReimondas ŠliterisUltrasound Institute, Kaunas University of Technology, Kaunas, LithuaniaLiudas MažeikaUltrasound Institute, Kaunas University of Technology, Kaunas, LithuaniaR. Van NieuwenhoveSCK-CEN, Studiecentrum voor Kernenergie-Centre dEtude de lEnergy Nucléare, Mol, BelgiumP. KupschusSCK-CEN, Studiecentrum voor Kernenergie-Centre dEtude de lEnergy Nucléare, Mol, BelgiumHamid Aı̈t AbderrahimSCK-CEN, Studiecentrum voor Kernenergie-Centre dEtude de lEnergy Nucléare, Mol, Belgium
2005en
ABI

Аннотация

In some nuclear reactors or accelerator-driven systems (ADS) the core is intended to be cooled by means of a heavy liquid metal, for example, lead-bismuth (Pb/Bi) eutectic alloy. For safety and licensing reasons, an imaging method of the interior of ADS, based on application of ultrasonic waves, has thus to be developed. This paper is devoted to description of developed various ultrasonic transducers suitable for long term imaging and measurements in the liquid Pb/Bi alloy. The results of comparative experimental investigations of the developed transducers of different designs in a liquid Pb/Bi alloy up to 450 degrees C are presented. Prototypes with different high temperature piezoelectric materials were investigated: PZT, bismuth titanate (Bi4Ti3O12), lithium niobate (LiNbO3), gallium orthophosphate (GaPO4) and aluminum nitride (A1N). For acoustic coupling with the metal alloy, it was proposed to coat the active surface of the transducers by diamond like carbon (DLC). The radiation robustness was assessed by exposing the transducers to high gamma dose rates in one of the irradiation facilities at SCK x CEN. The experimental results proved that the developed transducers are suitable for long-term operation in harsh conditions.

Перевод пока недоступен

Идентификаторы

Цитирования и источники

Цитирований: 2Использованных источников: 0