Sensitive and Selective Electrochemical Detection of Lead(II) Based on Waste-Biomass-Derived Carbon Quantum Dots@Zeolitic Imidazolate Framework-8

Qing LiuSchool of Environmental Science and Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, ChinaXiang GaoEngineering and Technology Center of Electrochemistry, School of Chemistry and Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, ChinaZhibao LiuEngineering and Technology Center of Electrochemistry, School of Chemistry and Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, ChinaLigang GaiEngineering and Technology Center of Electrochemistry, School of Chemistry and Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, ChinaYan YueEngineering and Technology Center of Electrochemistry, School of Chemistry and Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, ChinaHongfang MaSchool of Environmental Science and Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, China
2023en
ABI

Аннотация

An electrochemical sensor based on carbon quantum dots (CQDs) and zeolitic imidazolate framework-8 (ZIF-8) composite was fabricated to detect lead(II). The CQDs (2.47 ± 0.52 nm) were synthesized from platanus acerifoli leaves by carbonization and the hydrothermal method. Under the optimal conditions, the fabricated electrochemical sensor had excellent performance in detecting Pb2+. The linear range for Pb2+ was 1 nM–1 μM, and the limit of detection (LOD) was 0.04 nM and the limit of quantification (LOQ) was 0.14 nM. Moreover, when the solution contained Pb2+ and Cd2+, the linear range for Pb2+ was 50 nM to 1 μM and the LOD was 0.02 nM. When the solution contained Pb2+ and Cu2+, the linear range for Pb2+ was 50 nM–750 nM and LOD was 0.07 nM. Furthermore, even if the solution contained Pb2+, Cd2+ and Cu2+, the linear range for Pb2+ was 50 nM–1 μM and the LOD was 0.04 nM. The X-ray photoelectron spectroscopy (XPS), Fourier transform infrared spectrometer (FTIR) and Brunauer-Emmet-Teller (BET) results indicated that the composite electrode materials had abundant oxygen-containing functional groups, a large specific surface area and pore structure, which are conducive to the adsorption of heavy metal ions and improve the detection performance.

Перевод пока недоступен

Идентификаторы

Цитирования и источники

Цитирований: 2Использованных источников: 0