Перейти к основному содержанию
AkademIndex

Продукты

Для разработчиков

AkademBaseОткрытый API экосистемы
Статья

Vibration Analysis of Kenyir Dam Power Station Structure Using a Real Scale 3D Model

Azizi ArbainSchool of Mechanical Engineering, Engineering Campus, Universiti Sains MalaysiaAhmad Zhafran Ahmad MazlanSchool of Mechanical Engineering, Engineering Campus, Universiti Sains MalaysiaMohd Hafiz ZawawiDepartment of Civil Engineering, College of Engineering, Universiti Tenaga NasionalM. R. M. RadziTNB Generation Division, Tenaga Nasional Berhad
2019en
ABI

Аннотация

In this paper, the vibration analysis in terms of modal and harmonic responses are investigated for the power station structure of Kenyir Dam in Terengganu, Malaysia. Modal analysis is carried out to provide the dynamic characteristics of the power station which includes the natural frequencies and mode shapes. Meanwhile, the harmonic response analysis is performed by applying the force to the structure to obtain the Frequency Response Function (FRF) in certain range of frequencies. A real scale three-dimensional (3D) model of the Kenyir Dam power station is constructed using SolidWorks software and imported to ANSYS software for the Finite Element (FE) analysis. A proper boundary condition is taken into consideration to demonstrate the real behaviour of the power station structure. From the results, six most significant natural frequencies and mode shapes including the FRF in all three axes are selected. The highest natural frequency value occurred at 5.4 Hz with the maximum deflection of 0.90361 m in the <i>z</i> axis direction. This value is important in order to verify whether the structure can overcome the resonance phenomenon from the external disturbance forces in the future.

Перевод пока недоступен

Идентификаторы

Цитирования и источники

Цитирований: 2Использованных источников: 0