Перейти к основному содержанию
AkademIndex

Продукты

Для разработчиков

AkademBaseОткрытый API экосистемы
Статья

Study on Electromagnetic Transient Condition of EMU Passing by Phase-separation with Electric Load in High-speed Railway

Xiaoxu GuoSchool of Electrical Engineering, Southwest Jiaotong University, Chengdu, ChinaJianzhong WeiSchool of Electrical Engineering, Southwest Jiaotong University, Chengdu, ChinaLong XuSchool of Electrical Engineering, Southwest Jiaotong University, Chengdu, ChinaShibin GaoSchool of Electrical Engineering, Southwest Jiaotong University, Chengdu, ChinaZhengqing HanSchool of Electrical Engineering, Southwest Jiaotong University, Chengdu, China
2013en
ABI

Аннотация

Aiming at the complex electromagnetic transient process of EMU passing by phase-separation with electric load in high-speed railway, mechanism of overvoltage caused by switching off, overvoltage caused by switching on and impact current is analyzed systematically in this article. -type equivalent circuit of feeding section is put forward in the analysis of overvoltage mechanism. Overvoltage and overcurrent model of passing by phase-separation with electric load are also built. Correctness of mechanism was validated by simulation. In addition, the methods to solve the influence on substations, transformers and protection devices in this process are put forward, which provides a new idea on passing by phase-separation with electric load technology.

Перевод пока недоступен

Идентификаторы

Цитирования и источники

Цитирований: 3Использованных источников: 0