Перейти к основному содержанию
AkademIndex

Продукты

Для разработчиков

AkademBaseОткрытый API экосистемы
Статья

Smartphone-Based Electrochemical Immunoassay for Point-of-Care Detection of SARS-CoV-2 Nucleocapsid Protein

Ruijin ZengKey Laboratory of Analytical Science for Food Safety and Biology (MOE and Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou 350108, People’s Republic of ChinaMinghao QiuKey Laboratory of Analytical Science for Food Safety and Biology (MOE and Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou 350108, People’s Republic of ChinaQing WanSchool of Electronics and Information Engineering, Hubei University of Science and Technology, Xianning 437100, People’s Republic of ChinaZhisheng HuangSchool of Electronics and Information Engineering, Hubei University of Science and Technology, Xianning 437100, People’s Republic of ChinaXiaolong LiuThe United Innovation of Mengchao Hepatobiliary Technology Key Laboratory of Fujian Province, Mengchao Hepatobiliary Hospital of Fujian Medical University, Fuzhou 350025, People’s Republic of ChinaDianping TangKey Laboratory of Analytical Science for Food Safety and Biology (MOE and Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou 350108, People’s Republic of ChinaDietmar KnoppDepartment of Chemistry, Chair for Analytical Chemistry and Water Chemistry, Institute of Hydrochemistry, Technische Universität München, Lichtenbergstrasse 4, D-85748 Garching, Germany
2022en
ABI

Аннотация

Large-scale, rapid, and inexpensive serological diagnoses of severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2) are of great interest in reducing virus transmission at the population level; however, their development is greatly plagued by the lack of available point-of-care methods, leading to low detection efficiency. Herein, an ultrasensitive smartphone-based electrochemical immunoassay is reported for rapid (less than 5 min), low-cost, easy-to-implement detection of the SARS-CoV-2 nucleocapsid protein (SARS-CoV-2 N protein). Specifically, the electrochemical immunoassay was fabricated on a screen-printed carbon electrode coated with electrodeposited gold nanoparticles, followed by incubation of anti-N antibody (Ab) and bovine serum albumin as the working electrode. Accompanied by the antigen–antibody reaction between the SARS-CoV-2 N protein and the Ab, the electron transfer between the electroactive species [Fe(CN)6]3–/4– and the electrode surface is disturbed, resulting in reduced square-wave voltammetry currents at 0.075 V versus the Ag/AgCl reference electrode. The proposed immunoassay provided a good linear range with SARS-CoV-2 N protein concentrations within the scope of 0.01–1000 ng/mL (R2 = 0.9992) and the limit of detection down to 2.6 pg/mL. Moreover, the detection data are wirelessly transmitted to the interface of the smartphone, and the corresponding SARS-CoV-2 N protein concentration value is calculated and displayed. Therefore, the proposed portable detection mode offers great potential for self-differential diagnosis of residents, which will greatly facilitate the effective control and large-scale screening of virus transmission in resource-limited areas.

Перевод пока недоступен

Идентификаторы

Цитирования и источники

Цитирований: 2Использованных источников: 0