Integration of Kalina cycle in a combined heat and power plant, a case study

Sirko OgriseckInfraserv GmbH & Co. Hoechst KG, Industriepark Hoechst, Frankfurt am Main, Germany
2009en
ABI

Аннотация

Abstract\n This paper presents the integration of the Kalina cycle process in a combined heat and power plant for improvement of efficiency. In combined heat and power plants, the heat of flue gases is often available at low temperatures. This low-grade waste heat cannot be used for steam production and therefore power generation by a conventional steam cycle. Moreover, the steam supply for the purpose of heating is mostly exhausted, and therefore the waste heat at a low-grade temperature is not usable for heating. If other measures to increase the efficiency of a power plant process, like feed-water heating or combustion air heating, have been exhausted, alternative ways to generate electricity like the Kalina cycle process offer an interesting option. This process maximizes the generated electricity with recovery of heat and without demand of additional fuels by integration in existing plants. The calculations show that the net efficiency of an integrated Kalina plant is between 12.3 and 17.1 % depending on the cooling water temperature and the ammonia content in the basic solution. The gross electricity power is between 320 and 440 kW for 2.3 MW of heat input to the process. The gross efficiency is between 13.5 and 18.8 %.

Перевод пока недоступен

Идентификаторы

Цитирования и источники

Цитирований: 3Использованных источников: 0