A MTPA and Flux-Weakening Curve Identification Method Based on Physics-Informed Network Without Calibration
Haowen WangSchool of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, ChinaWei SunSchool of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, ChinaDong JiangSchool of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, ChinaRonghai QuSchool of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
2023en
ABI
Аннотация
In order to improve the efficiency, interior permanent magnet synchronous motors (IPMSMs) or the synchronous reluctance motors (SynRMs) need to be calibrated to obtain the maximum torque per ampere (MTPA) and flux-weakening (FW) curves. In industrial application, there are different types of IPMSMs and SynRMs. It is expensive and time-consuming to build test benches to calibrate each motor. In this letter, a physics-informed network is proposed to obtain the MTPA and FW operating curves. Only data from accelerating experiment, when motor operates without load, are adopted. The test bench is unnecessary. Experimental results show the validity of proposed method.
Перевод пока недоступен
Идентификаторы
Цитирования и источники
Цитирований: 3Использованных источников: 0