Crystal-field analysis of triply ionized rare earth ions in lanthanum trifluoride
Carole A. MorrisonU. S. Army Electronics Research and Development Command, Harry Diamond Laboratories, Adelphi, Maryland 20783Richard P. LeavittU. S. Army Electronics Research and Development Command, Harry Diamond Laboratories, Adelphi, Maryland 20783
1979en
ABI
Аннотация
Previously reported spectra of nine triply ionized lanthanides in LaF3 are analyzed by using a parametrized C2 crystal-field Hamiltonian. Initial crystal-field parameters Bnm in the fitting procedure were obtained from point charge lattice sums Anm using previously derived ρn, where Bnm=ρnAnm. The largest rms deviation of theory from experiment was 18.1 cm−1 (Pr3+), and the smallest was 2.1 cm−1 (Ho3+). The resulting Bnm were used to obtain a smoothed set of crystal field parameters for the entire lanthanide series whose largest rms deviation was 20.8 cm−1 (Pr3+) and whose smallest was 3.5 cm−1 (Ho3+).
Перевод пока недоступен
Идентификаторы
Цитирования и источники