Перейти к основному содержанию
AkademIndex

Продукты

Для разработчиков

AkademBaseОткрытый API экосистемы
Статья

Material classification from sparse spectral X-ray CT using vectorial total variation based on L infinity norm

Doniyor JumanazarovACCENT PRO 2000 s.r.l. (AP2K), Nerva Traian 1, K6, Ap. 26, Bucharest 031041, S3, RomaniaJakeoung KooTechnical University of Denmark, DTU Compute, 2800 Kgs. Lyngby, DenmarkJan KehresTechnical University of Denmark, DTU Physics, 2800 Kgs. Lyngby, DenmarkHenning Friis PoulsenTechnical University of Denmark, DTU Physics, 2800 Kgs. Lyngby, DenmarkUlrik L. OlsenTechnical University of Denmark, DTU Physics, 2800 Kgs. Lyngby, DenmarkM. IoveaACCENT PRO 2000 s.r.l. (AP2K), Nerva Traian 1, K6, Ap. 26, Bucharest 031041, S3, Romania
2022en
ABI

Аннотация

The development of energy resolving photon counting detectors (PCD) has paved the way to spectral X-ray Computed Tomography (CT), with which one can simultaneously extract the energy dependence of a material's linear attenuation coefficient (LAC). Spectral CT has proved to be an advanced technique to classify materials based on their physical properties such as electron density (ρe) and effective atomic number (Zeff). However, the application of spectral CT may be hindered by the poor image reconstruction quality when used for material identification in security screening where rapid scanning is required. Image reconstruction from few projections or low radiation exposure time would enable rapid scanning. The reconstruction quality for each energy bin may also be degraded since the division of photon counts into multiple energy bins naturally leads to higher noise levels. In this work, we explore how to perform accurate spectral CT reconstructions from such data, and propose L∞norm-based vectorial total variation (L∞-VTV) regularization that uses correlations between multiple energy bins. Using experimental data acquired with a custom laboratory instrument for spectral CT, the L∞-VTV is tested on “real life” phantoms consisting of materials in the range of 6 ≤ Zeff ≤ 15. For material classification from only 7 projections, the L∞-VTV gives the relative deviations of 3.5% for ρe and 2.4% for Zeff, whereas the total nuclear variation (TNV) of another state-of-the-art joint reconstruction and the total variation (TV) yield those of 3.4% and 3.1%, and 3.8% and 4.2%, respectively. The L∞-VTV is now ready for use in security screening.

Перевод пока недоступен

Идентификаторы

Цитирования и источники

Цитирований: 3Использованных источников: 0