Weiwei SongCollege of Hydrology and Water Resources, Hohai University, Nanjing 210098, ChinaYong PangCollege of Environment, Hohai University, Nanjing 210098, ChinaXiaohuan ShiQing XuSchool of Hydraulic, Energy and Power Engineering, Yangzhou University, Yangzhou 225009, China
2018en
ABI

Аннотация

The forebay of pumping stations is an important hydraulic structure that connects the channel with the inlet channel. Actual test observations and theoretical studies have shown that poor precursors produce backflow, vortex, and water flow disturbances in the forebay water. In this paper, taking a lateral inlet pump station as an example, we study the nonmeasures and five rectification measures—“Y” type diversion pier, “T” shaped diversion pier, narrow bottom hole, high and wide bottom, and diversion wall—through adopting the method of numerical simulation and model test. For the numerical simulation, the corresponding three-dimensional model is established by UG solid modeling software, and then the computational fluid is simulated numerically with CFX. Based on the analysis and comparison of the results during the test of numerical simulation and model test, the stability of the rectification measures is considered after taking into consideration the results of the uniformity test of the velocity distribution of the surface layer, the bottom layer, and the front section of each scheme. The proposed scheme <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M1"><mml:mrow><mml:mn fontstyle="italic">3</mml:mn></mml:mrow></mml:math> (“T” diversion pier) is regarded as the pumping station flow control measures.

Перевод пока недоступен

Идентификаторы

Цитирования и источники

Цитирований: 2Использованных источников: 0