Estimation of the Concentration of Low-Density Lipoprotein Cholesterol in Plasma, Without Use of the Preparative Ultracentrifuge
William T. FriedewaldBiometrics Research Branch (W.T.F.) and the Molecular Disease Branch (R.I.L. and D.S.F.), National Heart and Lung Institute, 9000 Rockville Pike, Bethesda, Md. 20014Robert I. LevyBiometrics Research Branch (W.T.F.) and the Molecular Disease Branch (R.I.L. and D.S.F.), National Heart and Lung Institute, 9000 Rockville Pike, Bethesda, Md. 20014Donald S. FredricksonBiometrics Research Branch (W.T.F.) and the Molecular Disease Branch (R.I.L. and D.S.F.), National Heart and Lung Institute, 9000 Rockville Pike, Bethesda, Md. 20014
1972en
ABI
Аннотация
Abstract A method for estimating the cholesterol content of the serum low-density lipoprotein fraction (Sf0-20) is presented. The method involves measurements of fasting plasma total cholesterol, triglyceride, and high-density lipoprotein cholesterol concentrations, none of which requires the use of the preparative ultracentrifuge. Comparison of this suggested procedure with the more direct procedure, in which the ultracentrifuge is used, yielded correlation coefficients of .94 to .99, depending on the patient population compared.