Перейти к основному содержанию
AkademIndex

Продукты

Для разработчиков

AkademBaseОткрытый API экосистемы
Статья

Impulse Response Method for Pipeline Systems Equipped with Water Hammer Protection Devices

Sang Hyun KimAssociate Professor, Dept. of Environmental Engineering, Pusan National Univ., San 30 Jangjundong Kumjunggu, Pusan, 609-735, Republic of Korea
2008en
ABI

Аннотация

Surge protection devices, such as surge tanks and air chambers, have been modeled with the impulse response method for transient analysis of water distribution systems. The lumped inertia model and continuity equation are used to represent nonpipe hydraulic elements. Results of pressure or discharge variations obtained by using the impulse response method and the method of characteristics are in good agreement. The impulse response method provides total pressure and discharge along any pipeline segment by direct integration of the ratio of complex head or complex discharge to a complex downstream discharge, respectively. A modification is proposed so that transition between turbulent and laminar flows can be considered. The representation of hydraulic devices has been incorporated into the impedance matrix method, which was developed for heterogeneous and multilooped pipe network systems. The potential advantages of the proposed method over other conventional approaches were investigated by applying the proposed method to hypothetical pipe network systems.

Перевод пока недоступен

Идентификаторы

Цитирования и источники

Цитирований: 2Использованных источников: 0