Investigation of the effect the concentration of phosphates in boiler water has on electrical conductivity and pH
Т. И. ПетроваMoscow Power Institute (MEI), Krasnokazarmennaya ul. 14, Moscow, 111250, RussiaV. I. KashinskiiMoscow Power Institute (MEI), Krasnokazarmennaya ul. 14, Moscow, 111250, RussiaA. E. VerkhovskiiMoscow Power Institute (MEI), Krasnokazarmennaya ul. 14, Moscow, 111250, RussiaПавел Александрович НиколаевMoscow Power Institute (MEI), Krasnokazarmennaya ul. 14, Moscow, 111250, RussiaD. A. RepinMoscow Power Institute (MEI), Krasnokazarmennaya ul. 14, Moscow, 111250, RussiaEugeniy ChernyshovS. L. Bogdanov
2007en
ABI
Аннотация
A correlation linking the concentration of phosphates in the boiler water of the clean and salt compartments, pH, and electrical conductivity was established as a result of tests carried out at OAO Mosenergo’s TETs-22 cogeneration station, and a mathematical description of this correlation is presented.
Перевод пока недоступен
Идентификаторы
Цитирования и источники
Цитирований: 2Использованных источников: 0