Calculating the parameters of automatic control systems featuring highly accurate operation
V. Ya. RotachMoscow Power Institute (MEI), Krasnokazarmennaya ul. 14, Moscow, 111250, Russia
2006en
ABI
Аннотация
It is shown that a controller’s tuning can be optimized for the criterion of minimizing the root-mean square control error without knowing the correlation function of input signals if it is required that the error be considerably smaller than it is without control. Otherwise, virtually unrealistic durations of input signals may be required for the correlation function to be evaluated with necessary accuracy.
Перевод пока недоступен
Идентификаторы
Цитирования и источники
Цитирований: 2Использованных источников: 0