Перейти к основному содержанию
AkademIndex

Продукты

Для разработчиков

AkademBaseОткрытый API экосистемы
Статья

The effects of surgical preparation techniques and implant macro-geometry on primary stability: An in vitro study

Giovanni FalisiDepartment of Life, Health, and Environmental Sciences, School of Dentistry, University of L'Aquila, Piazzale Salvatore Tommasi 1, 67100 Coppito (AQ), L'Aquila, Italy, [email protected]Marco SeverinoMD. Department of Life, Health, and Environmental Sciences, School of Dentistry, University of L'Aquila, L'Aquila, ItalyC RastelliMD. Department of Life, Health, and Environmental Sciences, School of Dentistry, University of L'Aquila, L'Aquila, ItalySara BernardiPhD. Department of Life, Health, and Environmental Sciences, School of Dentistry, University of L'Aquila, L'Aquila, ItalySilvia CarusoDDS. Department of Life, Health, and Environmental Sciences, School of Dentistry, University of L'Aquila, L'Aquila, ItalyMassimo GalliMD Department of Oral and Maxillofacial Sciences, "Sapienza" University of Rome, ItalyLuca LamazzaMD Department of Oral and Maxillofacial Sciences, "Sapienza" University of Rome, ItalyCarlo Di PaoloMD Department of Oral and Maxillofacial Sciences, "Sapienza" University of Rome, Italy
2017en
ABI

Аннотация

BACKGROUND: The attainment of a good primary stability is a necessary condition to ensure the success of osseointegration in implantology. In type IV cancellous bone, however, it is possible that a reduced primary stability can lead to an increased rate of failure. The aim of this study was therefore to determine, with the help of the resonance frequency (Osstell mentor), which technique of implant site preparation (piezo surgery, conventional, under-preparation, bone compaction, osteodistraction) and macro-geometry is able to improve implant stability in type IV cancellous bone. MATERIAL AND METHODS: 10 pig ribs were prepared with a surgical pre-drilled guide, calibrated for a correct implant positioning. On each rib, 5 implant sites (one for each technique) were prepared. Successively, 50 conical implants (Tekka Global D) were inserted and measured with the resonance frequency to evaluate the primary stability. Data collected were analyzed by analysis of variance (ANOVA) to test whether the Implant Stability Quotient (ISQ) values of the five techniques were significantly different. RESULTS: The results showed that no significant differences among the ISQ values of the five techniques used were found. Also, no significant differences in the macro-geometry of the two types of compared implants were observed. However, the macro-geometry of Tekka implants, characterized by a double condensing thread, seems to provide greater ISQ values than those of single thread implants when using the same technique. CONCLUSIONS: In light of these preliminary data, it is conceivable that in cases of reduced stability, such as those occurring with a type IV bone, all means ameliorating the primary stability and accelerating the osseointegration can be utilized.

Перевод пока недоступен

Идентификаторы

Цитирования и источники

Цитирований: 2Использованных источников: 0