Study on the measurement technique of Fe foil's activated γ spectrum
Wang DalunInstitute of Nuclear Physics and Chemistry,CAEP,P
ABI
Аннотация
In this article it is comparatively systematically studied on the related measurement technique of Fe foil's activated γ spectrum and resolving-spectrum under specifical conditions, including high-threshold-energy detectors, self-absorption, self-sheilding and perturbation and so on. The experimental results and the calculated results with MCNP code are analyzed and also discussed.