Асосий контентга ўтиш
AkademIndex

Маҳсулотлар

Ишлаб чиқувчилар учун

AkademBaseЭкотизим учун очиқ API
Мақола

An explorative study of polymers for 3D printing of bioanalytical test systems

Christoph JurischkaChair of Multiparametric Diagnostics, BTU Cottbus - Senftenberg, Senftenberg, GermanyFranziska DinterChair of Multiparametric Diagnostics, BTU Cottbus - Senftenberg, Senftenberg, GermanyAnastasia EfimovaChair of Inorganic Chemistry, BTU Cottbus - Senftenberg, Senftenberg, GermanyRomano WeissChair of Multiparametric Diagnostics, BTU Cottbus - Senftenberg, Senftenberg, GermanyJuliane SchiebelChair of Multiparametric Diagnostics, BTU Cottbus - Senftenberg, Senftenberg, GermanyChristian SchulzProject Group Pz-Syn, Fraunhofer Institute for Cell Therapy and Immunology, Branch Bioanalytics and Bioprocesses IZI-BB, Potsdam, Germany Located at the BTU Cottbus - Senftenberg, Senftenberg, GermanyBekzodjon FayzievChair of Mathematical Modeling, Samarkand State University, Samarkand, UzbekistanPeter SchierackChair of Multiparametric Diagnostics, BTU Cottbus - Senftenberg, Senftenberg, GermanyThomas FischerStudy Program Forensic Sciences and Engineering, BTU Cottbus - Senftenberg, Cottbus, GermanyStefan RödigerChair of Multiparametric Diagnostics, BTU Cottbus - Senftenberg, Senftenberg, Germany
ABI

Аннотация

BACKGROUND: The 3D printing is relevant as a manufacturing technology of functional models for forensic, pharmaceutical and bioanalytical applications such as drug delivery systems, sample preparation and point-of-care tests. OBJECTIVE: Melting behavior and autofluorescence of materials are decisive for optimal printing and applicability of the product which are influenced by varying unknown additives. METHODS: We have produced devices for bioanalytical applications from commercially available thermoplastic polymers using a melt-layer process. We characterized them by differential scanning calorimetry, fluorescence spectroscopy and functional assays (DNA capture assay, model for cell adhesion, bacterial adhesion and biofilm formation test). RESULTS: From 14 tested colored, transparent and black materials we found only deep black acrylonitrile-butadiene-styrene (ABS) and some black polylactic acid (PLA) useable for fluorescence-based assays, with low autofluorescence only in the short-wave range of 300-400 nm. PLA was suitable for standard bioanalytical purposes due to a glass transition temperature of approximately 60°C, resistance to common laboratory chemicals and easy print processing. For temperature-critical methods, such as hybridization reactions up to 90°C, ABS was better suited. CONCLUSIONS: Autofluorescence was not a disadvantage per se but can also be used as a reference signal in assays. The rapid development of individual protocols for sample processing and analysis required the availability of a material with consistent quality over time. For fluorescence-based assays, the use of commercial standard materials did not seem to meet this requirement.

Ҳали таржима қилинмаган

Мавзулар

Идентификаторлар

Иқтибослар ва манбалар

Кўрсаткичлар — AkademScholar · Тез орада