Corneal shape changes after vitreoretinal surgery with fluid–gas exchange

Akira WatanabeDepartment of Ophthalmology, The Jikei University School of Medicine, Tokyo, JapanWakana NinomiyaThis is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC), where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc/4.0Kei MizobuchiInformed consent was obtained from all individual participants included in the studyTomoyuki WatanabeThis study complied with the Declaration of Helsinki and was approved by the Ethics Committee of The Jikei University School of Medicine. (28-166[8409])Tadashi NakanoThis study complied with the Declaration of Helsinki and was approved by the Ethics Committee of The Jikei University School of Medicine. (28-166[8409])
Medicinejournal2022en
ABI

Аннотация

ABSTRACT: To investigate changes in the corneal shape caused by fluid-gas exchange after vitrectomy.This retrospective case-control study included 43 eyes that underwent a combination of cataract surgery and vitrectomy. The corneal shape was measured using anterior segment optical coherence tomography CASIA2. The corneal shape measurements were performed preoperatively, 1 day, 1 week, 1 month, and 3 months after surgery. After calculating the real K value from the actual measured values of the posterior shape of the corneal refracting power and the single posterior corneal refracting power value, Fourier analysis values were examined. Fluid-gas exchange was performed in 23 eyes (gas group), while it was not performed in 20 eyes (nongas group).There was a significant increase in the real K value in the regular and asymmetry components (0.61 ± 0.36, 0.82 ± 0.64) in the gas group only on the first day after surgery (Steel-Dwass test; P < .05). There was also a significant increase in the real K value in the higher-order irregular astigmatism components (Steel-Dwass test; P < .05) for longer periods in the gas versus the nongas group. The shape of the posterior cornea increased in all components in the gas group on the first day after surgery (spherical power -6.35 ± 0.20, regular astigmatism 0.32 ± 0.12, asymmetry 0.22 ± 0.13, and higher-order irregular astigmatism 0.12 ± 0.05, Steel-Dwass test; P < .05).Postoperative changes caused by surgical invasion in the corneal shape appeared to be greater in the gas versus the nongas group, in addition to affecting the time periods of the postoperative corneal shape changes.

Ҳали таржима қилинмаган

Мавзулар

Идентификаторлар

Иқтибослар ва манбалар