U. T. AshrapovPhD, senior researcher, Institute of Nuclear Physics of Academy Sciences, Tashkent, UzbekistanB. B. MirzaevPhD, senior researcher, Institute of Nuclear Physics of Academy Sciences, Tashkent, UzbekistanV. NesterovPhD, Chief Specialist, JSC «Research Institute of Technical Physics and Automation», Moscow, Russia
ABI

Аннотация

<pre><strong>Abstract</strong></pre> <pre>The article discusses the experience work of specialists of the consortium as part of the INP AS (Tashkent, Uzbekistan), JSC " JSC «Research Institute of Technical Physics and Automation»" and CJSC "Mounting Firm "Radiy" (Moscow, Russia) at utilization of 96 pieces of sources GIK-7-2 Co-60 of gamma installations of "RKhM-gamma-20" and "Issledovatel", including 2 emergency sources Co-60, their burial in specialization point for radioactive waste. Also, the experience of specialists in the elimination of emergency situation with recharge a highly active source of GIK 8-4 Co-60 for radiation gamma therapy from emergency holder with crack to a new holder from depleted uranium. The reason for the appearance of a crack on the body of the Co-60 source holder is discussed.</pre>