Experimental investigation of cooling performance in electronic instruments

Mohammed BensafiLaboratory of Energetic in Arid Zones (ENERGARID), University Tahri Mohamed of Bechar, Bechar, AlgeriaNoureddine KaidDepartment of Technology, University Center Salhi Ahmed Naama (Ctr. Univ. Naama), Naama, AlgeriaAmmar H. ShnawaCollege of Engineering, National University of Science and Technology, Dhi Qar, IraqAbdulrhman M. AlsharariDepartment of Physics, University of Tabuk, Tabuk, Saudi ArabiaKarrar Shareef MohsenInformation and Communication Technology Research Group, Scientific Research Center, Al-Ayen University, Thi-Qar, IraqAli AkgülDepartment of Mathematics, Art and Science Faculty, Siirt University, Siirt, Turkey + Department of Electronics and Communication Engineering, Saveetha School of Engineering, SIMATS, Chennai, Tamilnadu, IndiaBarno AbdullaevaTashkent State Pedagogical University named after Nizami, Tashkent, UzbekistanYounes MenniDepartment of Technology, University Center Salhi Ahmed Naama (Ctr. Univ. Naama), Naama, AlgeriaHussein ShanakDepartment of Physics, Faculty of Applied Science, Palestine Technical University - Kadoorie, Tulkarm, Palestine
Thermal Sciencejournal2023en
ABI

Аннотация

This study explores the principle of producing cold through heat absorption at a temperature lower than ambient temperature, which requires the use of an endothermic mechanism. Specifically, the study focuses on evaluating multiple thermoelectric coolers using aluminum water heat exchangers as a means of validating a proposed correlation through a series of experiments. The system utilizes water as a coolant and a thermoelectric cooler coupled with a heatsink to cool it. The cooling power of the system is controlled by adjusting the temperatures of the hot and cold heatsinks and the coolant flow through the heat exchanger based on governing equations. In addition to assessing the cold-side temperature, the research also investigates the system COP of the thermoelectric system. The results indicate that a thermoelectric cooler with a lower thermal resistance is more effective at cooling and can achieve a lower cold-side temperature. Conversely, a cold-side heatsink with a higher thermal resistance provides lower cooling power. Two experiments were conducted to acquire comprehensive data on the thermoelectric devices, and the obtained results and experience were used to categorize the utilization of the Peltier model. The first experiment achieved an 84% success rate, while the second experiment achieved a rate of around 97- 95%, highlighting the potential for further experimentation with alternative configurations.

Ҳали таржима қилинмаган

Мавзулар

Идентификаторлар

Иқтибослар ва манбалар