Investigation the formation of a spark discharge from a layer of deposited dust on a grounded electrode and dependence of air purification degree on the potential electrode voltage
Shavkat MuzafarovNational Research University “Tashkent Institute of Irrigation and Agricultural Mechanization Engineers”, Tashkent, UzbekistanVladlen BalitskyNational Research University “Tashkent Institute of Irrigation and Agricultural Mechanization Engineers”, Tashkent, UzbekistanAziz BabayevNational Research University “Tashkent Institute of Irrigation and Agricultural Mechanization Engineers”, Tashkent, UzbekistanO G KilichovNational Research University “Tashkent Institute of Irrigation and Agricultural Mechanization Engineers”, Tashkent, UzbekistanNusratillo ToshpulatovNational Research University “Tashkent Institute of Irrigation and Agricultural Mechanization Engineers”, Tashkent, UzbekistanAzamat TabaevNational Research University “Tashkent Institute of Irrigation and Agricultural Mechanization Engineers”, Tashkent, UzbekistanOrifjon SattorovNational Research University “Tashkent Institute of Irrigation and Agricultural Mechanization Engineers”, Tashkent, Uzbekistan
ABI
Аннотация
This article presents the methodology and results of experimental studies of the formation of a spark discharge from a layer of deposited dust on a grounded electrode and the dependence of the degree of air purification on the voltage at the potential electrode. Based on the research results, the limiting density of the deposited dust and the need to clean the precipitation electrode from the deposited dust layer, as well as the use of spark protection circuits, were determined. It was also revealed that the level of fluctuation of the mains voltage practically does not affect the degree of purification of the air stream from dust.
Ҳали таржима қилинмаган
Мавзулар
Идентификаторлар
Иқтибослар ва манбалар
0 та иқтибос2 та фойдаланилган манба