Selecting The Most Suitable Stage For Filter Integration In A Multi-Stage Dust Purification System
Аннотация
This study investigated the efficiency of separating technological dust generated in cotton ginning plants using two-stage cyclones - SS-6 and SP-1.5. According to practical measurements, it was found that the dust separation efficiency of the SS-6 cyclone was 70.8%, and that of the SP-1.5 cyclone was around 51.3%. The overall efficiency of this two-stage system was 92.5%. At the same time, taking into account high environmental requirements, it is recommended to introduce an additional filtration stage. The three-stage cleaning system allows for more than 99% dust retention, which is important for increasing production efficiency and reducing environmental impact.
Ҳали таржима қилинмаган