Pressure calibration of diamond anvil Raman gauge to 310GPa

Yuichi AkahamaUniversity of Hyogo Graduate School of Material Science, , 3-2-1 Kouto, Kamigohri, Hyogo 678-1297, JapanHaruki KawamuraUniversity of Hyogo Graduate School of Material Science, , 3-2-1 Kouto, Kamigohri, Hyogo 678-1297, Japan
2006en
ABI

Аннотация

In order to develop an optical method for pressure determination in the multimegabar region, the first-order Raman spectra of diamond anvils were investigated at pressures up to 310GPa. The high-frequency edge of the Raman band, which corresponds to the Raman shift of the anvil culet due to the normal stress, was calibrated against the sample pressure derived from the equation of state of Pt. The obtained pressure dependence of the edge frequency demonstrates the reliability of this diamond anvil Raman gauge. Up to the maximum pressure of this study, the relation between Raman frequency and normal stress at the diamond anvil culet is formally similar to the equation of state of a hydrostatically compressed isotropic elastic body having a bulk modulus of K0=547(11)GPa and a pressure derivative of the bulk modulus K0′=3.75(20).

Ҳали таржима қилинмаган

Идентификаторлар

Иқтибослар ва манбалар

2 та иқтибос0 та фойдаланилган манба