Asosiy kontentga oʻtish
Maqola

Radiative heat transfer on the peristaltic flow of an electrically conducting nanofluid through wavy walls of a tapered channel

S. R. MishraDepartment of Mathematics, Siksha ‘O’ Anusandhan Deemed to be University, Khandagiri, Bhubaneswar 751030, Odisha, IndiaSubhajit PandaDepartment of Mathematics, National Institute of Technology, Mizoram 796012, IndiaS. VigneshP. K. PattnaikOdisha University of Technology and ResearchVediyappan GovindanDepartment of Mathematics, Hindustan Institute of Technology and Science (Deemed to be University), Padur, Kelambakkam 603103, IndiaJagadish V. TawadeDepartment of Mathematics, Vishwakarma University, Pune 411048, Maharashtra, IndiaM. Ijaz KhanDepartment of Mechanical Engineering, Lebanese American University, Beirut, LebanonDilsora AbduvalievaDoctor of Philosophy in Pedagogical Sciences, Tashkent State Pedagogical University, Bunyodkor avenue, 27, Tashkent 100070, UzbekistanImen BouazziCollege of Engineering, King Khalid University, Saudi Arabia
Results in Physicsjournal2023en
Ochiq kirishOltin

Litsenziya: cc-by

ABI

Annotatsiya

Present analysis deals with the characteristics of radiative heat on the peristaltic flow of nanofluid through wavy walls of a tapered channel. Peristaltic flows within the pumping process arise in the region having lower to higher pressure region. Assumption of velocity slip along with the convective boundary condition energizes the thermal system as well as the flow phenomena. However, the combined effect of Brownian motion and thermophorsis due to the cross-diffusion effect affects the flow properties. One of the significant applications of the flow is that the blood pumping in the human body. It acts as a vehicle through the liquid that past through the wavy channels walls contacting liquids expands in its length due to the dynamical rush. However, solution of the transformed governing flow phenomena is obtained by employing approximate analytical technique known as Variation Parameter Method (VPM). The characteristics of the parameters involved in the system are presented via graphs. Present outcome warrants that, the significance of magnetic strength and flow through the permeable medium may favours to enhance the pumping procedure as the pressure gradient lower down in the non-Darcy medium found to be one of the important observations. Further, significant enhancement in the fluid temperature and concentration profile is exhibited due to the consideration of the convective conditions i.e. the augmentation in the thermal and solutalBiot numbers respectively.

Hali tarjima qilinmagan

Mavzular

Identifikatorlar

Iqtiboslar va manbalar