Asosiy kontentga oʻtish
Maqola

Study on the impact of intermittent heating control strategy system on greenhouse thermal environment

Mingzhi ZhaoCollege of Energy and Power Engineering, Inner Mongolia University of Technology, Hohhot 010051, ChinaYingjie LiuEngineering Center of Solar Energy Utilization Technology, Inner Mongolia University of Technology, Hohhot 010051, ChinaZheng HanSchool of Physics and Intelligent Manufacturing Engineering, Chifeng University, Chifeng 024000, ChinaChun ChangEngineering Center of Solar Energy Utilization Technology, Inner Mongolia University of Technology, Hohhot 010051, ChinaDaorina BaoCollege of Energy and Power Engineering, Inner Mongolia University of Technology, Hohhot 010051, ChinaRasakhodzhaev Bakhramzhan SabirovichNational Scientific Institute of Renewable Energy Source Under Ministry of Energy of the Republic of Uzbekistan, Bodomzor yoli Str., 2-B, 100084 - Tashkent, UzbekistanAkhadou JobirNational Scientific Institute of Renewable Energy Source Under Ministry of Energy of the Republic of Uzbekistan, Bodomzor yoli Str., 2-B, 100084 - Tashkent, Uzbekistan
2025en
Ochiq kirishOltin

Litsenziya: cc-by

ABI

Annotatsiya

The heating imbalance in solar-powered heating greenhouses (SHG) severely constrains both energy supply efficiency and crop yield. This study proposes the principle of Thermal Intermittent Heating (TIH), unveiling the differentiated regulatory mechanisms by which the duty cycle ( ) governs thermal dynamics in both aerial greenhouse environments and subsurface soil layers. Under the greenhouse thermal environment conditions, the operational mode with =0.67 (control scheme (2,1)) demonstrates optimal thermal stratification adaptation through an 8-hour heating/4-hour intermittent cycle. This configuration achieved the highest Comprehensive Energy Energy Efficiency Index (COP) of 88.7% in the fourth layer (group maximum), along with minimal thermal fluctuations indicated by (2.82°C) and (11.12%). The strategy effectively compensates for thermal dissipation in upper zones caused by buoyant airflow (48% elevation in mean temperature), while preventing excessive top-layer overheating observed in continuous heating ( =1) scenarios, which exhibited 128% surge in . Within the soil layer (0.1-0.2m depth), this value synchronously optimizes thermal penetration intensity and stability: The first-layer COP reached 182.39 ( =19.72°C) with merely 1.85°C, where heating duration precisely matched the soil's thermal diffusion period (6-8 hours). Whereas =1 induced 197% surge in soil (5.51°C vs. optimal condition), and =0.13 resulted in 22.6% reduction in deep-layer temperature mean. The study demonstrates COP's capacity to quantify heterogeneous thermal responses across media, revealing that moderate =0.67 regulates thermal inertia to achieve multi-objective synergy in "energy consumption-uniformity-thermal penetration". This establishes a thermodynamic analysis framework for hierarchical heating system optimization.

Hali tarjima qilinmagan

Identifikatorlar

Iqtiboslar va manbalar