Asosiy kontentga oʻtish
Maqola

A blockchain-enabled IoT framework for smart electro-medical waste management

K. Suresh KumarComputer Science and Engineering, Sri Eshwar College of Engineering, Coimbatore, 641202, IndiaT. Ananth KumarComputer Science and Engineering, IFET College of Engineering, Villupuram, 605108, IndiaChristo AnanthFaculty of Artificial Intelligence and Digital Technologies, Samarkand State University, 140104, Samarkand, UzbekistanMathiyazhagan NarayananDepartment of Biotechnology, Research and Innovation, Saveetha School of Engineering, Saveetha Institute of Medical and Technical Science, Chennai, 602105, IndiaHari Mohan RaiDepartment of Computer Science, School of Engineering and Digital Sciences, Nazarbayev University, 010000, Astana, Kazakhstan. [email protected]Saurabh AgarwalSchool of Computer Science and Engineering, Yeungnam University, Gyeongsan, 38541, Republic of Korea. [email protected]Wooguil PakSchool of Computer Science and Engineering, Yeungnam University, Gyeongsan, 38541, Republic of Korea. [email protected]
2026en
ABI

Annotatsiya

Electro-medical waste (EMW) management presents critical challenges related to traceability, regulatory compliance, and operational safety in healthcare environments, where improper handling can pose serious risks to public health and the environment. To address these challenges, this work proposes a blockchain-integrated Internet of Things framework, termed BIOT-EMW, which combines IoT sensing, blockchain-based auditability, and edge-level intelligence to enable secure and transparent EMW lifecycle management. A convolutional neural network-based computer vision module is deployed at the edge to automate EMW classification and reduce manual intervention. The performance evaluation of the proposed BIOT-EMW system emphasizes system-level operational metrics, including latency, delay, bandwidth, power consumption, resource utilization, and scalability, rather than exhaustive model-level benchmarking. Experimental results show that edge-level processing latency ranges from 3.45 to 9.33 ms, end-to-edge communication delay from 6.43 to 12.11 ms, bandwidth usage from 24.54 Mbps to 34.87 Mbps, and device-level power consumption from 6.5 to 13.31 mW, with resource utilization between 78 and 92% and scalability reaching up to 97%. In a prototype-scale experimental testbed, the BIOT-EMW framework shows feasible and efficient operation with promising scalability for automated electro-medical waste management in smart healthcare facilities.

Hali tarjima qilinmagan

Identifikatorlar

Iqtiboslar va manbalar