Experimental evaluation of dynamic characteristics of strain gauge pressure transducers under pulsed vibration effects

K. JurayevaZamira NazirovaDepartment of Power Supply , Tashkent State Transport University , 1 Temiryulchilar St. , Tashkent , 100167 , UzbekistanK. SattarovDepartment of Electronics and Radiotechnics , Tashkent University of Information Technologies named after Muhammad al-Khwarizmi , Tashkent , Uzbekistan
2026en
ABI

Annotatsiya

This paper presents an experimental approach for evaluating the dynamic characteristics of strain gauge pressure transducers under pulsed ultrasonic (vibration-like) excitation using spectral transfer-function identification without prior knowledge of the emitter frequency response. Two silicon-sapphire strain gauge pressure transducers with different sensing-element designs (types A and B, nominal range 0-100 kPa) were tested. The estimated normalized frequency responses show distinct resonance patterns: type A exhibits pronounced maxima at approximately 6.4, 23.5, and 68.6 kHz with peak normalized magnitude H f ≈ 0.99, 0.56, and 0.88, respectively, whereas type B shows a smoother response with the dominant maximum near 44.4 kHz ( H f ≈ 0.44). The peak response of type A is about 2.3× higher than that of type B, indicating higher susceptibility to vibration-induced dynamic errors in the corresponding bands. The proposed technique supports comparative assessment of vibration resistance and dynamic measurement errors under controlled laboratory broadband excitation.