Asosiy kontentga oʻtish
Maqola

Beyond Dissolved Oxygen: Integrated Assessment of Multistage Vortex Aeration Effects on Urban Reservoir Water Quality

Javokhirbek EralievDepartment of ICT Integrated Smart Safe Ocean City Engineering, Dong-A University, Busan 49315, Republic of KoreaJavokhirbek Murodjon Ugli MamatkobulovDepartment of ICT Integrated Smart Safe Ocean City Engineering, Dong-A University, Busan 49315, Republic of KoreaArnab GhoshDepartment of ICT Integrated Smart Safe Ocean City Engineering, Dong-A University, Busan 49315, Republic of KoreaJiwook ChoiUrban Redevelopment Division, Saha-gu, Busan 49328, Republic of KoreaА. БабаевDepartment of Engineering Communications and Systems, Tashkent State Transport University, Temiryulchilar 1, Tashkent 100000, UzbekistanTanushree PaulDepartment of Civil Engineering, Dong-A University, Busan 49315, Republic of KoreaJaebum KimJoons Engineering Co., Ltd., 376, Mayu-ro, Siheung 15055, Republic of KoreaJun Cheol JeonMinistry of Ocean and Fisheries, Busan 48789, Republic of KoreaSung Hyuk ParkDepartment of Civil Engineering, Dong-A University, Busan 49315, Republic of Korea
2026en
Ochiq kirishOltin

Litsenziya: cc-by

ABI

Annotatsiya

Aeration is widely used to increase the oxygen concentration in urban reservoirs, but its broader effect on nutrients, organic matter, and integrated water quality status remains uncertain. This study evaluated the response of the Jangrim reservoir, Busan, South Korea, to a multistage vortex aerator (MVA) using monthly monitoring data from the Water Environment Information System by the Ministry of Environment from 2020 to 2025. The dataset was divided into pre-MVA and post-MVA periods, and water quality changes were assessed using descriptive statistics, box plots, percentage change, time-series regression, Pearson’s correlation analysis, principal component analysis, and three water quality indices: CCME-WQI, RT-WQI, and NSF-WQI. After MVA installation, dissolved oxygen increased from 8.7 mg/L, corresponding to a 72.4% increase. TN and TP decreased by 41.2% and 59.6%, respectively. In contrast, organic matter indicators showed mixed responses: BOD decreased by 18.8%, whereas COD and TOC increased by 4.6% and 13.2%, respectively. WQI scores improved after MVA operation, but CCME-WQI remained in the Poor class. PCA showed that urban pond system water quality was controlled by oxygen-related, nutrient, and organic–particulate factors. Overall, MVA improved oxygen conditions and partially reduced nutrient pressure, but aeration alone was insufficient for full urban pond system restoration.

Hali tarjima qilinmagan

Identifikatorlar

Iqtiboslar va manbalar

0 ta iqtibos0 ta foydalanilgan manba