Asosiy kontentga oʻtish
Maqola

High-efficiency particulate separation from cotton-ginning exhaust air using an inclination-assisted multi-cyclone system

Ahror TursunovNamangan State Technical University, Namangan 160115, UzbekistanJasur ShodmanovNamangan State Technical University, Namangan 160115, UzbekistanNosir SharibaevNamangan State Technical University, Namangan 160115, UzbekistanSherzod DjurayevNamangan State Technical University, Namangan 160115, UzbekistanSherzod KorabayevNamangan State Technical University, Namangan 160115, UzbekistanSabohat ErgashkhojayevaNamangan State Technical University, Namangan 160115, UzbekistanMuhammmadyusuf XolmatovNamangan State Technical University, Namangan 160115, UzbekistanHong-Tao LiuState Key Laboratory of New Textile Materials and Advanced Processing, School of Material Science & Engineering, Wuhan Textile University, Hubei Province 430200, PR China
2026en

Ochiq kirish: yoʻq

ABI

Annotatsiya

This study presents the design, CFD-assisted optimization, and industrial evaluation of an inclination-assisted multi-cyclone system for particulate removal from cotton-ginning exhaust air. A patented two-stage system comprising a six-body primary multi-cyclone with inclined inlets and continuous screw-conveyor dust discharge, followed by pulse-jet-cleaned secondary filtration, was evaluated under full-scale operating conditions at the Kosonsoy Cotton Ginning Plant, Uzbekistan. Computational fluid dynamics (CFD) simulations predicted stable flow distribution among the cyclone bodies and strong internal swirling-flow structures and were used as an engineering design-support tool rather than as a quantitatively field-validated aerodynamic model. A randomized 23 full-factorial experiment showed that secondary-filter diameter significantly affected collection efficiency and specific cleaning time, while cyclone inclination angle significantly affected cleaning time and exhibited a weaker effect on collection efficiency that approached, but did not exceed, the adopted 95% significance threshold. Inlet velocity showed no statistically significant effect within the investigated range. The best-performing constrained operating point within the tested design domain was 14 m s⁻¹, 10°, and 200 mm. At this operating point, the integrated two-stage system achieved a measured TSP mass-based collection efficiency of 98.3% between the system inlet and final clean-air outlet. This value represents the combined system performance and not the standalone efficiency of the inclined primary multi-cyclone. Theoretical Lapple analysis suggested a cut size of approximately 8 μm, although no size-resolved PM₂.₅ or PM₁₀ collection efficiencies were measured. A site-specific comparison with the existing field-operated SP-6 installation showed a 91.5% reduction in seasonal TSP emissions and an additional capture of 54,900 kg of particulate matter. Model-based temperature-sensitivity analysis using Sutherland’s viscosity relationship and the Lapple framework predicted decreasing separation efficiency with increasing temperature; this relationship was not independently validated using temperature-resolved TSP measurements. Under the adopted economic scenario, the proposed system yielded an estimated net seasonal benefit of 895.4 million UZS. As a single-site, single-season proof-of-concept study, these findings demonstrate substantial TSP-emission reduction together with industrial and economic feasibility under the investigated conditions. A comprehensive assessment of actual energy performance and environmental sustainability requires direct power measurements and dedicated life-cycle assessment, respectively.

Hali tarjima qilinmagan

Identifikatorlar

Iqtiboslar va manbalar