Hamza Farhan Abu OwidaMedical Engineering Department, Faculty of Engineering, Al-Ahliyya Amman University, Amman, 19328, JordanSuleiman Ibrahim MohammadResearch follower, INTI International University, Putra Nilai, Negeri Sembilan, 71800, MalaysiaAsokan VasudevanFaculty of Business and Communications, INTI International University, Nilai, Negeri Sembilan, 71800, MalaysiaChethan MDepartment of Physics & Electronics, School of Sciences, JAIN (Deemed to be University), Bangalore, Karnataka, IndiaPraveen Priyaranjan NayakDepartment of Electronics & Communication Engineering, Siksha ’O’ Anusandhan (Deemed to be University), Bhubaneswar, Odisha, 751030, IndiaPankaj TripathiDepartment of Physics, Sharda University, knowledge Park III, Greater Noida, IndiaGaganjot KaurDepartment of Electronics and Communication Engineering, Chandigarh University, Mohali, Punjab, IndiaFaiz MahmoodDepartment of chemistry from university of Education, Lahore, PakistanRasulbek Jumyazovich EshmetovDepartment of Natural science, Mamun University Khiva, Khiva, UzbekistanSaeid MohebiYoung Researchers and Elite Club, Tehran Branch, Islamic Azad University, Tehran, Iran
2026en
Ochiq kirishOlmos

Litsenziya: cc-by-nc-nd

ABI

Annotatsiya

Photoelectrochemical (PEC) biosensing has emerged as a powerful analytical platform by integrating photonic excitation with electrochemical detection, offering high sensitivity, low background signals, and excellent compatibility with semiconductor nanomaterials. This review systematically examines the roles of CdSe quantum dots (QDs) in advanced PEC biosensing, addressing the current lack of an integrated understanding of the relationships among their physicochemical properties, signal transduction mechanisms, and ratiometric sensing performance. Particular emphasis is placed on the interplay between electronic structure, interfacial charge transfer, surface engineering, and photocurrent generation, which collectively determine sensing efficiency and analytical reliability. Recent advances in nanocomposite engineering and biofunctional interface design are further analyzed to demonstrate their contributions to enhancing sensitivity, selectivity, and operational stability. In addition, emerging ratiometric sensing strategies are discussed as effective approaches for minimizing environmental interference and improving quantitative accuracy. Current challenges associated with surface defects, material stability, and practical implementation are also highlighted, together with future perspectives that support the rational design of next-generation CdSe QD-based PEC biosensing platforms for biomedical, environmental, and food analysis.

Hali tarjima qilinmagan

Identifikatorlar

Iqtiboslar va manbalar

0 ta iqtibos0 ta foydalanilgan manba