Does Hydroxyapatite Reinforce Conventional Glass Ionomer Cements? A Systematic Review of In Vitro Evidence on Mechanical Properties
Annotatsiya
Background: This systematic review evaluated the effects of hydroxyapatite (HA), as the sole added filler, on the mechanical properties of conventional glass ionomer cements (GICs). Methods: PubMed/MEDLINE, Scopus, Web of Science, EBSCOhost and Google Scholar were searched up to 13 July 2026 following PRISMA 2020 (PROSPERO CRD420251079759). Two reviewers independently performed study selection, data extraction and risk-of-bias assessment using RoBDEMAT. Heterogeneity in HA characteristics, concentration, powder-to-liquid ratio and testing protocols precluded meta-analysis. Results: of 1816 records identified, 22 studies met the eligibility criteria. Compressive strength was higher than that of the unmodified cement in 6 of 13 studies, lower in 4 and unchanged in 3. Flexural strength was higher in 6 of 7 studies and diametral tensile strength in 3 of 5, in at least one tested formulation. Surface microhardness findings were inconsistent, with higher values in 2 of 6 studies, lower values in 2 and no clear change in 2. Fracture toughness was assessed in a single study. Improvements were most consistent at about 5 wt% HA, but the response varied with particle characteristics and the host cement, and no optimal concentration could be identified. Conclusions: HA effects on GIC mechanical properties depend on formulation and testing conditions.
Hali tarjima qilinmagan