Asosiy kontentga oʻtish
Maqola

Multiphysics Modeling of Metronidazole Electroreduction at Polypyrrole/ ZIF ‐67 Porous Electrodes: Linking Porosity, Transport, and Kinetics

Rima Heider Al OmariFaculty of Allied Medical Sciences, Hourani Center for Applied Scientific Research Al‐Ahliyya Amman University Amman JordanG. Nalini PriyaDepartment of Chemistry and Biochemistry, School of Sciences JAIN (Deemed to be University) Bangalore Karnataka IndiaSubhashree RayInstitute of Medical Sciences and Sum HospitalTalal Aziz QassemDepartment of Medical Laboratory Technics, College of Health and Medical Technology Alnoor University Mosul IraqGunjan GargCentre for Research Impact & Outcome, Chitkara University Institute of Engineering and Technology, Chitkara University Rajpura Punjab IndiaRenu SharmaDepartment of Chemistry, University Institute of Sciences Chandigarh University Mohali Punjab IndiaZokir AtaullaevNatural Science Department Urganch State Pedagogical Institute Urgench UzbekistanRasul UsmanovDepartment of Chemistry Urgench State University Urgench UzbekistanNaser Aslanian
2026en
ABI

Annotatsiya

ABSTRACT Understanding the coupling between porous architecture, molecular transport, and interfacial kinetics is essential for improving metronidazole (MNZ) electrochemical detection. This study investigates MNZ electroreduction at polypyrrole (PPy) nanotube/ZIF‐67‐modified electrodes using a two‐dimensional axisymmetric multiphysics framework incorporating transient diffusion, porous‐medium transport, and concentration‐dependent cathodic kinetics. The effective‐medium description incorporates accessible porosity and tortuosity, yielding a prescribed diffusivity dependence of D eff ∝ ε 2.5 . Porosity was varied from 0.2 to 0.8 to examine transport–reaction interactions under controlled operating conditions. The corrected analytical limiting‐current formulation predicts a 32‐fold increase in geometrically normalized current density across this interval, distinguishing constitutive transport scaling from coupled numerical behavior. Kinetic parameterization employed an effective charge‐transfer coefficient of 0.48 and reference exchange‐current densities within (0.8–1.4) × 10 −6 A cm −2 . Concentration‐dependent experimental comparisons were organized into calibration and validation conditions, with a reported maximum normalized root mean square error of 0.072. Sensitivity analysis identified porosity as the most influential parameter near the reference operating state, while finite perturbations revealed stronger interval‐dependent responses. The detection‐limit analysis was formulated using calibration sensitivity and a prescribed baseline‐noise standard deviation of 0.1 nA, providing conditional theoretical estimates rather than independently validated analytical detection limits. The findings establish a physically interpretable framework for assessing porous‐layer transport resistance, interfacial reactant availability, and potential‐dependent kinetic limitations in PPy/ZIF‐67‐based electrochemical sensing.

Hali tarjima qilinmagan

Identifikatorlar

Iqtiboslar va manbalar