Asosiy kontentga oʻtish
Maqola

A SIMPLIFIED METHOD FOR CALCULATING A SECTION OF A SINGLE-LINE HEATING NETWORK WITH A MODERN HEAT EXCHANGER

Ismatulla Khujaevглавный научный сотрудник Института механики и сейсмостойкости сооружений, АН РУз, Узбекистан, г. ТашкентZiyomat ShirinovИнститута механики и сейсмостойкости сооружений, АН РУз, Узбекистан, г. Ташкент
2024en
ABI

Annotatsiya

Based on the hypothesis that the coolant flows along the outer contour of a multi-section radiator, and the coolant defends in the internal vertical pipes, methods for hydraulic and thermal calculation of a multi-section radiator have been developed. The quadratic law of resistance and analogues of Kirchhoff's laws were used to calculate the distribution of costs over arcs and nodal pressures. When describing the temperature change in showers with a coolant flow, the Shukhov formula and the results of solving the problem of heat transfer in vertical intermediate cylindrical pipes with an internal resting coolant and an external atmosphere are used. For heat exchangers with a limited number of sections, the results of numerical calculations were obtained and analyzed, in particular, for the loss of pressure and heat in the section with the heat exchanger.

Hali tarjima qilinmagan

Identifikatorlar