Enhancing energy security through optimization of hybrid energy systems with improved reliability and sustainability

Md. Sabbir AlamBUBT Research Graduate School, Bangladesh University of Business and Technology, Dhaka, BangladeshMd Ashraful IslamFaculty of Electrical and Electronics Engineering Technology, Universiti Malaysia Pahang Al-Sultan Abdullah (UMPSA), Pekan, Pahang 26600, MalaysiaIan B. BenitezElectrical Engineering Department, College of Engineering, FEU Institute of Technology, Manila, PhilippinesSamariddin MakhmudovDepartment of Economics, Mamun University, Khiva 220900, UzbekistanAripov AzizStrategic Planning Department, Kimyo International University, Tashkent, UzbekistanMohd Shawal JadinFaculty of Electrical and Electronics Engineering Technology, Universiti Malaysia Pahang Al-Sultan Abdullah (UMPSA), Pekan, Pahang 26600, MalaysiaAhmed Al MansurDepartment of Electrical and Electronic Engineering, Bangladesh University of Business and Technology, BangladeshAymen FlahApplied Science Research Center, Applied Science Private University, Amman 11931, Jordan
2026en
Ochiq kirishOltin

Litsenziya: cc-by

ABI

Annotatsiya

Decentralized hybrid renewable energy systems can improve energy security in rural regions where grid supply is limited. This study designs and evaluates a grid-connected photovoltaic (PV)-biogas system for Ghatail, Bangladesh. The design is based on a field survey of 221 consumers (946.82 kWh/day, 78 kW peak demand) and the livestock waste of 21 farms (135 t/month). HOMER Pro was used to determine the optimal configurations, and the results were verified with the Grey Wolf Optimizer (GWO) and the Whale Optimization Algorithm (WOA) under identical inputs and constraints. Techno-economic, reliability, sustainability and energy security indicators were evaluated together with sensitivity analysis. Two configurations, each with a 150-kW PV array and a 102-kW converter, were identified. With a 100-kW biogas generator, the system achieved the lowest net present cost (NPC) of $290,932, a levelized cost of energy (LCOE) of $0.0197/kWh, a renewable fraction (RF) of 99.8% and grid purchases of only 0.174% of annual supply. With a 50-kW generator, the LCOE was $0.04/kWh and the RF 87.3%, with a shorter break-even period of 2.84 years. Both configurations met the full demand with a loss of power supply probability of zero and reduced CO₂ emissions by 81.3% and 99.6%, respectively, compared with grid-only supply. GWO and WOA converged to solutions within 2.2% of the HOMER NPC. Across all sensitivity scenarios, the 100-kW configuration maintained an RF above 99% and an LCOE of $0.017–0.024/kWh.

Hali tarjima qilinmagan

Identifikatorlar

Iqtiboslar va manbalar