GateMPC: identifying a canal gate law from an open archive, and what it costs predictive control
Annotatsiya
At a gated canal structure the published continuous discharge is not a measurement: it is the output of a rating equation, so checking a gate law against that series is a tautology that returns a near-perfect fit. This deposit holds the detector for that circularity, its confirmation at a second structure whose rating takes a different form, the non-circular check against independent field gaugings, and a closed-loop measurement of what a controller loses by carrying the benchmark's gate law. It ships the normalised USGS data package the results are computed from, the scripts that compute them, the tests, and a desktop application that shows the results and applies the method to a structure of the reader's own. This is the source tree of https://github.com/Adilbaygh/GateMPC at tag v1.0.0, commit 197dcf5af32ff44e0ccf768a80c635792943178b. The code is under the MIT licence; the data package under DATA/ is released under CC0.
Hali tarjima qilinmagan