Asosiy kontentga oʻtish
Maqola

Generation of Coherent X-rays in the Water Window Using 5-Femtosecond Laser Pulses

Christian SpielmannN. H. Burnett and C. Kan, Department of Electrical Engineering, University of Alberta, Edmonton T6G 2G7, CanadaN. H. BurnettP. Wobrauschek, Atominstitut der Österreichischen Universitäten, Schüttelstrasse 115, A-1020 Wien, AustriaS. SartaniaCh. Spielmann, S. Sartania, R. Koppitsch, M. Schnürer, M. Lenzner, F. Krausz, Abteilung Quantenelektronik und Lasertechnik, Technische Universität Wien, Gusshausstrasse 27, A-1040 Wien, AustriaR. KoppitschP. Wobrauschek, Atominstitut der Österreichischen Universitäten, Schüttelstrasse 115, A-1020 Wien, AustriaM. SchnürerP. Wobrauschek, Atominstitut der Österreichischen Universitäten, Schüttelstrasse 115, A-1020 Wien, AustriaC. KanCh. Spielmann, S. Sartania, R. Koppitsch, M. Schnürer, M. Lenzner, F. Krausz, Abteilung Quantenelektronik und Lasertechnik, Technische Universität Wien, Gusshausstrasse 27, A-1040 Wien, AustriaM. LenznerN. H. Burnett and C. Kan, Department of Electrical Engineering, University of Alberta, Edmonton T6G 2G7, CanadaP. WobrauschekN. H. Burnett and C. Kan, Department of Electrical Engineering, University of Alberta, Edmonton T6G 2G7, CanadaFerenc KrauszCh. Spielmann, S. Sartania, R. Koppitsch, M. Schnürer, M. Lenzner, F. Krausz, Abteilung Quantenelektronik und Lasertechnik, Technische Universität Wien, Gusshausstrasse 27, A-1040 Wien, Austria
1997en

Ochiq kirish: yoʻq

ABI

Annotatsiya

Coherent extreme-ultraviolet radiation extending to wavelengths below the carbon K edge at 4.37 nanometers (nm) has been generated at a repetition rate of 1 kilohertz by focusing 5-femtosecond near-infrared (780 nm) laser pulses into a helium gas jet. The incident light field performs just a few oscillations, which results in the emission of an x-ray supercontinuum rather than discrete harmonics. Owing to the extremely short rise time of the driving pulses, neutral atoms can be exposed to high fields before they are depleted by ionization. As a result, the observed x-ray radiation extends well into the water window and is delivered in a well-collimated beam (divergence less than 1 milliradian). The high repetition rate and spatial coherence result in a brightness of about 5 × 10 8 photons per square millimeter per square milliradian per second in a 1-percent bandwidth at 4.37 nm, the carbon edge of the water window. The compact laboratory system holds promise as a source for biological holography and nonlinear optics in the x-ray regime.

Hali tarjima qilinmagan

Identifikatorlar

Iqtiboslar va manbalar

10 ta iqtibos0 ta foydalanilgan manba