Enhancing Visual Comfort and Energy Efficiency in Office Lighting Using Parametric-Generative Design Approach for Interactive Kinetic Louvers

Seyed Morteza HosseiniDepartment of Architecture, Design & Media Technology, Aalborg University Copenhagen, DenmarkMilad HeiranipourDepartment of Energy, Politecnico di Torino, Turin, ItalyScuola Universitaria Superiore IUSS Pavia, Pavia, ItalyDepartment of Architectural Engineering, Penn State University, United StatesJulian WangDepartment of Architectural Engineering, Penn State University, United StatesLaura HinkleDepartment of Architecture, Design & Media Technology, Aalborg University Copenhagen, DenmarkGeorgios TriantafyllidisSustainable Building Design Lab, Dept. UEE, Faculty of Applied Science, University of Liege, Liege, BelgiumShady AttiaSustainable Building Design Lab, Dept. UEE, Faculty of Applied Science, University of Liege, Liege, Belgium
2024en
ABI

Annotatsiya

The number of desk workers who frequently conduct their jobs at home has increased dramatically during Covid-19. Work-from-home flexibility makes it attractive for workers and companies, resulting in a “Work-Style Reform” after the Covid-19 pandemic. However, the quick conversion of home spaces into workplaces cannot always sufficiently respond to users’ visual comfort and daylight performance needs which are primary contributors to occupant well-being and productivity. Therefore, this study adopts a mixed-methodology method that integrates parametric thinking, biomimetic, conceptual design, kinetic strategy and the DIVA approach to develop a real-time parametric-generative circular design for multi-objective adaptability that optimizes visual comfort and electric lighting energy efficiency for multiple occupants simultaneously. Parametric simulations of 1458 different options (five different runs per case: a total of 7290) were conducted to assess how the louvers perform regarding daylight, glare, and electric energy usage. Implementing an interactive kinetic louver greatly improved daylight performance in all orientations while simultaneously avoiding visual discomfort for multiple occupants. Furthermore, the use of this façade modification resulted in a substantial decrease in electrical lighting energy consumption, reducing the values from 14.22 to 0.2 kWh/m2/year, 8.1 to 0.18 kWh/m2/year, and 12.88 to 0.18 kWh/m2/year for South, East, and West orientations, respectively. Integrating users' lighting level preferences and the dynamic transitory sensitive area on the façade considerably reduces electric lighting consumption by around 99% compared to the ASHRAE 90.1 standard's lighting profile.

Hali tarjima qilinmagan

Identifikatorlar

Iqtiboslar va manbalar