Asosiy kontentga oʻtish
Preprint

Characterisation of the ILMT 4K x 4K TDI CCD imager

Gokul Singh MehraAryabhatta Research Institute of Observational Sciences (ARIES) , Manora Peak , Nainital - 263002 , IndiaBhavya AilawadhiAryabhatta Research Institute of Observational Sciences (ARIES) , Manora Peak , Nainital - 263002 , IndiaTalat AkhunovUlugh Beg Astronomical Institute of the Uzbek Academy of Sciences , Astronomicheskaya 33 , 100052 Tashkent , UzbekistanMonalisa DubeyMahatma Jyotiba Phule Rohilkhand University , Pilibhit Bypass Road , Bareilly 243006 , Uttar Pradesh , IndiaNaveen DukiyaAryabhatta Research Institute of Observational Sciences (ARIES) , Manora Peak , Nainital - 263002 , IndiaSara FilaliInstitute of Astrophysics and Geophysics , Liège University , Allée du 6 Août 19c , 4000 Liège , BelgiumPaul HicksonDepartment of Physics and Astronomy , The University of British Columbia , 6224 Agricul- tural Road , Vancouver , BC V6T 1Z1 , CanadaPriyanshi KumariAryabhatta Research Institute of Observational Sciences (ARIES) , Manora Peak , Nainital - 263002 , IndiaKuntal MisraAryabhatta Research Institute of Observational Sciences (ARIES) , Manora Peak , Nainital - 263002 , IndiaVibhore NegiKavli Institute for Astronomy and Astrophysics , Peking University , Beijing 100871 , ChinaKumar PranshuAryabhatta Research Institute of Observational Sciences (ARIES) , Manora Peak , Nainital - 263002 , IndiaJean SurdejAryabhatta Research Institute of Observational Sciences (ARIES) , Manora Peak , Nainital - 263002 , IndiaSarvesh Kumar Yadav
2026en
ABI

Annotatsiya

In this work, we determine the gain and read-out noise of the 4Kx4K CCD imager used with the 4-m International Liquid Mirror Telescope (ILMT). Due to the zenith-pointing characteristic of the telescope, the CCD operates in the Time Delay Integration (TDI) mode for image acquisition. The CCD frames obtained during rising twilight have non-uniform illumination and can potentially be used to calculate important CCD parameters using two approaches. The first approach directly measures variance in flux along rows with minimum horizontal gradient, despite the strong vertical illumination gradient. The second method divides the CCD frame into regions exposed to similar background illumination and analyses the flux ratio variation between the two regions. Mathematically, we establish a linear relationship between the signal variance and average flux, from which gain is determined, while the read-out noise (RON) is measured independently from the bias frames. Both methods provide a gain value of approximately 3.9 e/ADU, while the RON measured from bias frames is 1.55 ADU (~ 6 e). Estimation of these parameters provides a better understanding of the CCD performance and allows for an accurate calibration.

Hali tarjima qilinmagan

Identifikatorlar

Iqtiboslar va manbalar

0 ta iqtibos0 ta foydalanilgan manba