MAGNETIC RECORDER FOR NUCLEAR PULSE APPLICATION. Final Report Covering Period: June 5, 1959 to June 5, 1960
G.M. Burgwald~tomic Energy Commission Lemont, WinoisC. Addison StoneARMOUR RESEARCH FOUNDATION OF ILLINOIS \INSTITUTE
1960en
ABI
Annotatsiya
An analog recording technique was investigated in which pulses from a scintillation counter are stretched to a width compatible with the bandwidth of the recorder. Three types of playback systems were considered, i.e., unequalized velocity, equalized velocity, and flux sensitive playback. The results of the three systems were found to be comparable. Loss in resolution in the process was primarily due to nonuniformities in magnetic tape properties and maintenance of an adequate head to tape contact. Instrumental line widths of the order of 3% were achieved using equipment of moderate cost. (For preceding period see ARF- 1151-5.) (auth)