D-T Neutron Penetrating Quality Measurement of Iron and Engineering Plastic(In Chinese)

Zhu ChuanxinInstitute of Nuclear Physics and Chemistry,CAEP,Mianyang,621900)
ABI

Annotatsiya

Cylindrical samples of iron(the model is Q235)and engineering plastic were irradiated using D-T neutron source at ns-200 accelerator,the sample isφ30 cm×10 cm.The neutron penetration of samples were measured withφ5.08 cm×5.08 cm BC501A liquid scintillator detector.The environment neu- tron background has been measured and deduced using shadow-cone method. The energy linearity of detector system was scaled by ~(22)Na standardγ/source. The neutron flux at the target was monitored using associated-αparticle meth- od.γbackground was deduced by(n,γ)pulse shape discrimination technolo- gy.In low energy region,the neutron count loss caused by(n,γ)discrimina- tion is corrected by Gauss simulation through two-dimension MCA system.The iron's D-T neutron penetration is 0.408 and the engineering plastic's is 0.73. It is showed that D-T neutron penetrating quality of the engineering plastic is superior to the iron's.

Hali tarjima qilinmagan

Mavzular

Iqtiboslar va manbalar

0 ta iqtibos0 ta foydalanilgan manba